The ArKang AKAV6302 is a high-performance anesthesia machine engineered to meet the demanding requirements of modern surgical and critical care settings. Combining electronic control with pneumatic drive, this anesthesia machine delivers precise ventilation management, robust safety features, and an intuitive user interface. Its compact mobile design with locking casters enhances maneuverability, making it suitable for operating rooms, ICUs, and emergency departments.
1. High-Resolution Display & User Interface
Equipped with a 12.1-inch LCD screen, this anesthesia machine provides clear visualization of real-time waveforms including:
Pressure-Time (P-T)
Flow-Time (F-T)
Volume-Time (V-T)
Pressure-Volume (P-V), Volume-Flow (V-F), and Flow-Pressure (F-P) loops
The display supports zoom, comparison, and freeze functions, enabling detailed analysis of ventilation dynamics.
2. Comprehensive Ventilation Modes
The anesthesia machine supports a wide range of ventilation modes to accommodate diverse clinical needs:
VCV – Volume Controlled Ventilation
SIMV-V – Synchronized Intermittent Mandatory Ventilation-Volume
SIMV-P – Synchronized Intermittent Mandatory Ventilation-Pressure
MANUAL
A/C – Assist/Control Ventilation
PCV – Pressure Control Ventilation
PSV – Pressure Support Ventilation
STAND-BY
3. Advanced Ventilation Parameters & Control
Tidal Volume Range: 20–1500 mL
Pressure Range: 5–60 cmH₂O
Respiration Rate: 1–100 bpm (1–40 bpm under SIMV)
I:E Ratio: 4:1–1:8
PEEP Range: OFF, 3–30 cmH₂O (electronic control)
Pressure Trigger Range: –20 to +20 cmH₂O (based on PEEP)
Flow Trigger: 0–15 L/min
Minute Volume: >18 L/min
SIGH Range: 0–5 per 100 breaths
Inspiratory Plateau: Adjustable
4. Precision Gas Delivery System
Flowmeter: 5-tube cascade system with ranges:
O₂: 0.1–15 L/min
N₂O: 0.1–15 L/min
Air: 0.1–15 L/min
Vaporizer: 2 Selectatec mounts compatible with Isoflurane, Enflurane, Sevoflurane, and Halothane
Fresh Gas Compensation: 25–75 L/min
CO₂ Absorber Volume: 2 L
5. Integrated Safety Systems
Hypoxic Guard System: N₂O cut-off valve ensures O₂ concentration >25%
Safety Valve: Pressure limit <12.5 kPa
O₂/Air Failure Alarm: Visual and audio alerts
Power Failure Backup: Battery supports ≥180 minutes of operation
Automatic Calibration & Self-Test
6. Monitoring & Alarm Capabilities
Monitored Parameters:
VT, MV, BPM, Paw, Lung Compliance, Inspiratory Plateau, FiO₂
Alarm Limits (Audio/Visual):
No tidal volume
Minute volume limits
Airway pressure limits
FiO₂ limits
O₂/Air supply failure
AC power failure
Low battery
7. Optional Accessories & Connectivity
AGSS – Anesthetic Gas Scavenging System
Suction Unit
Communication Interfaces: Ethernet, USB, VGA
Auxiliary Oxygen Meter
Pipeline Gas Configuration: O₂, N₂O, Air (280–600 kPa input)
| Category | Specification |
|---|---|
| Model | AKAV6302 |
| Brand | ArKang |
| Dimensions (W×D×H) | 70 × 85 × 140 cm |
| Weight | 65 kg |
| Casters | Front wheels with lock |
| Screen | 12.1-inch LCD |
| Power Supply | AC 220V ±10%, 50Hz ±2% |
| Battery Runtime | ≥180 minutes |
| Pipeline Input | 280–600 kPa (O₂, N₂O, Air) |
| Working Type | Electronic control, pneumatic driven |
| Patient Range | Adult & Pediatric |
| Ventilation Modes | VCV, SIMV-V, SIMV-P, MANUAL, A/C, PCV, PSV, STAND-BY |
| Tidal Volume | 20–1500 mL |
| Pressure Range | 5–60 cmH₂O |
| Respiratory Rate | 1–100 bpm (1–40 bpm under SIMV) |
| I:E Ratio | 4:1–1:8 |
| PEEP Range | OFF, 3–30 cmH₂O (electronic) |
| Flow Trigger | 0–15 L/min |
| Minute Volume | >18 L/min |
| Flowmeter Tubes | 5 (O₂, N₂O, Air: 0.1–15 L/min each) |
| Vaporizer Mounts | 2 (Selectatec) |
| CO₂ Absorber Volume | 2 L |
| Hypoxic Guard | O₂ >25%, N₂O cut-off |
| Safety Valve Pressure | <12.5 kPa |
| Fresh Gas Compensation | 25–75 L/min |
| Language | English |
| Calibration | Automatic |
| Optional Accessories | AGSS, Suction Unit, Ethernet/USB/VGA, Auxiliary O₂ Meter |
| Shipping Origin | Guangzhou, China |
| MOQ | 1 unit |