Core advantages
I.The pet icu incubator has stable power and environmental adaptation
Wide power supply guarantee: supports 220V±10%, 50Hz±2% power supply, input power 5400VA, can adapt to the power environment of different regions and different diagnosis and treatment scenarios, ensure stable operation of the equipment, and provide continuous care support for pets.
Wide environmental adaptability: During transportation and storage, it can be stored in a temperature of -10℃-40℃ and a humidity of ≤95%; during operation, it is suitable for a temperature of 18℃-30℃ and a humidity of 30%-75%, and can flexibly cope with the differences in the internal and external environments of pet hospitals.
II.The pet icu incubator can accurately control the temperature
Flexible temperature control range: The temperature in the cabin can be accurately controlled at 15℃-38℃, and can be raised to 39℃ under special operations to meet different care needs such as postoperative rewarming and disease cooling, such as maintaining a warm environment of about 37℃ for weak pets after surgery to help the body recover.
Fine temperature management: temperature fluctuation ≤0.8℃, average temperature difference of monitoring chamber ≤1.0℃, control accuracy up to ±0.5℃, heating time 5-20min, creating stable and comfortable temperature conditions for pets, reducing stress response caused by temperature fluctuations.
III. The pet intensive care unit is equipped with safety and low noise design
Multiple safety protection: leakage current of the whole machine is ≤0.5mA in normal state, ≤1mA in single fault state, with 1500V/50Hz withstand voltage test (no breakdown or flashover for 1 minute), ensuring the safety of pets and operators; monitoring room noise ≤30dB, creating a quiet environment, reducing pet anxiety and stress.
Power supply
Power supply voltage: 220V±10%/50Hz±2%
Input power: 5400VA
Ambient temperature: 10℃ - 35℃
Temperature control range
Cabin temperature: 15℃ - 38℃ (up to 39℃ under special operation)
Temperature fluctuation: ≤0.8℃
Monitoring chamber average temperature: ≤1.0℃
Cabin temperature control accuracy: ≤±0.5℃
Warm-up time: 5min - 20min
Monitoring room noise: ≤30dB
Equipment leakage current: ≤0.5mA (normal state); ≤1mA (single fault state)
Withstand voltage: 1500V/50Hz, no breakdown and flashover for 1 minute
Environmental conditions
Transportation and storage
Ambient temperature: -10℃ - 40℃
Relative humidity: ≤95%
Operating conditions
Ambient temperature: 18℃ - 30℃
Relative humidity: 30% - 75%